can you login to one of the client PC and see if there is any WMI namespace created and see cm_localgroupmembers ? Great work on this! Open the SQL Management Studio. Script pipes all the admin users to WMI and send that info to sccm for that computer. Perhaps I am going about it the wrong way, but I cannot get the queries to work; I keep getting a syntax error. But if you use Windows on another language? I would lilke to know if it's something I'm doing or a change in the way custom views are created. if it is cl, Hi Balaji, Glad you find this useful. SCCM 2012 user and device collections membership rule queries There is no need for choosing objects when creating collections. Is there a way to inject the current OS of the PC in this script? adsgdis.log doesn't show any clear indication of an issue during delta. These 2 will help you what is going on. 1. 3.Run SQL query /report to get members of local administrators group. I checked SQL views manually and they have data for only this one server. It seems the vbscript posted for Sherry it is not updated to grab the "Disabled" information, am I pointed to wrong directions? Hi Matt, If you want all the users in same row ,you can use something forxml code in SQL so you get right number there. Since the script that is used in the configuration item will create the instance in wmi âcm_localgroupmembers â and query local groups with its members 1 time per script run ,which means if you run the configuration item 1 time ,it will query local groups and members and pipe the information into cm_localgroupmembers ,but if any changes happened after the compliance item run ,they wont appear in cm_localgroupmembers . In WMI i see data. One final thing to note - I did find that in order for the VBScript to run properly on Windows 10, I had to change the TempFolder (line 10 in the VBS script) to manually point to C:\Windows\Temp\, otherwise the logfile didn't want to show up for me, and the WMI objects never got created, even though the script should have been running. Getting this error on client machines in "Inventoryprovider.log" log file. For the uninstall collections create a query to list the devices that have the application installed and the device/user is no longer a member of the AD group. Enabling delta discovery for Active Directory groups. I tried in CMCB 1802 and it works .Have you tried checking client wmi if there is any info loaded there also check the inventoryagent.log for further troubleshooting. order by sys1.netbios_name0, lgm.name0, lgm.account0, Hi Eswar, does the currently downloadable vbs script include the âdisabledâ info? oDataObject.Properties_.add "Domain" , wbemCimtypeString For examle: Russian, Italian, English and Germany Since we have already started the process I need to go back and check the PC's already done. We need to link our collection to our application. strComputer = wshNetwork.ComputerName Is the view created and is empty? If Domain = strComputer Then and lgm.account0 not in ('Domain Admins','wintelMonitoring','WintelAdmins','eskonr') and sys1.Name0='clientname' But getting below error, "GetPropertyListForClassName - Failed to get class 'C00000000_0000_0000_0000_000000000011' from WMI namespace. Where are you importing the client settings ? Linking security groups to SCCM deployments will give your environment flexibility with application installations. save it as .vbs . Oh and I don't need to inject the PC name, just the OS. This command gets the query membership rule named Remote Users By Domain from device collection named Remote Users. I can evaluate and it shows Compliant when I view. I don't quite get your next step that says "Logging information by Script".. many thanks!! You can download the files from http://eskonr.com/wp-content/uploads/2017/03/SCCMLocalGroupMembers.zip or simply download the baseline and import into SCCM but dont forget to update mof files. oNewObject.Type = Type1 Dim wbemCimtypeString I have created everything based on your instruction, however I am running into an issue where no data is being populated into the SQL Db. On the Query Rule properties window, you can now view the query. did you check dataldr.log if the mof changes you made are successfully compiled ? 5/13/2018 6:20:00 PM - Found 24 Local Groups where lgm.name0='Administrators' Domain = arrUserBits(0) This complexity can make it difficult to use, especially when you just want to deploy an application. Would you be so kind to add it? arrUserBits = Split(strUserPath, "/") oNewObject.Account = objMember.Class SELECT DISTINCT SMS_R_System.NetbiosName, SMS_G_System_OPERATING_SYSTEM.BuildNumber FROM SMS_R_System INNER JOIN ⦠I am attaching the configuration baseline cab file here for you to download ,extract ,import into your configmgr 2012 or configmgr current branch 1610 and simply deploy to your required collection, import MOF file into client agent settings for hardware inventory. if you have deployed the baseline onetime ,you will not get updated results . Type: String: Aliases: Id: Position: Named: Default value: None: Accept pipeline input: False: Accept wildcard characters: False-CollectionName. Include Membership collection Rule SQL Query. Because after creating a user or device collection on microsoft system center configuration manager 2012 there would be objects that is created newly on your network infrastructure. http://eskonr.com/wp-content/uploads/2017/03/Local-Admin-BaselineMOF-file.zip. If so how did you, Please assist, I'm running this and I can see the entry in the config man on the targeted computer but I do not see the log file being created. I've just got through this myself. Now we have sufficient information about the local users ,member of all local groups which is stored in SQL view âv_gs_localgroupmembers0â . I have not looked at it though but you can give a try. New features in NAKIVO Backup & Replication v10.2, Specops Password Policy 7.5: Enforce good password use in Active Directory, EventSentry v4.2: Identifying insecure configurations with a hybrid SIEM, Specops Password Auditor: Find weak Active Directory passwords, XEOX: Managing Windows servers and clients from the cloud, SmartDeploy: Rethinking software deployment to remote workers in times of a pandemic, PowerShell 7 delegation with ScriptRunner, Remote Desktop Manager: A powerful and full-featured connection manager, Microsoft Most Valuable Professional (MVP), Outlook attachments now blocked in Office 365, PolicyPak MDM Edition: Group Policy and more for BYOD, Creating an AD group-based collection with PowerShell, Export and import Windows Subsystem for Linux (WSL), https://blog.codonomics.com/2020/09/setting-default-user-for-imported-wsl.html, Error changing time zone in Windows Server 2019: Use the command line or PowerShell instead, Strings in PowerShell – Replace, compare, concatenate, split, substring, Microsoft 365 deadline: Nine months to upgrade older Office versions, Top Stories from the Microsoft DevOps Community 2021.02.12 | Azure DevOps Blog, Computer object is added to AD Security Group, SCCM AD Group Discovery "Delta Discovery" runs (Default, 5 min), Can be set to Incremental defined as "periodically" (what's the actual interval? Note: You will need to replace âGRP_Groupâ with your AD group name. I think "SCCM-Group-members.zip\Local Admin Group only\script.txt" has a bug. The below query is used for creation of a device collection based on device membership of a security group within Active Directory. Hi - I was testing this at home lab. Quite common (based on all the blog-articles) is to set an Incremental update for ⦠Next. Specify System Resource as the attribute class and System Group Name as the attribute. Notify me of followup comments via e-mail. I've deployed this with success in my environment, but at the time I did it, the option "disabled" was not active in the hardware inventory classes because we didn't need it. hi, I am having a bit of trouble with this DCM script - I have imported and configured everything fine, and it actually works great within DCM. Here's my understanding, but would appreciate confirmation. Any other messages are welcome. Query 2: List members of the local Administrators group on specific client: select sys1.netbios_name0 This is hos a collection query for linux / unix computers look like in SCCM. I Am having the same issue. Limit language features, secure communication, track abuse. try with this link http://eskonr.com/wp-content/uploads/2017/03/SCCMLocalGroupMembers.zip . This data has come in handy a number of times so itâs certainly ⦠Please redownload the attachment ,import the MOF file into client settings ,it should work for you this time. Ran into the same issue. Hi, ,lgm.domain0 [Domain for Account] This is something to look at the database side for the reporting. set oNewObject = oServices.Get("WIN32_localadmins") Create configuration item,configuration baseline and deploy to collection on recurring basis. Occurs every hour by default. dataldr.log is no error. if you want to get information for local accounts with its status etc, you can expand the vbscript to write information to wmi and expand the mof file to query this to database. What are some troubleshooting steps for group memberships not being discovered with the delta discovery? you will get the OS information from SCCM database with resourceID/hostname from v_r_system_Valid or v_gs_operating_system. is there a way to confirm that this is an inherent issue with the latest CB versions? Right-click your collection and select Deploy – Application. (sorry for my English). Its been more than a week since I configured it. Copy this group name, as you will be pasting it quite a bit in the upcoming steps. Wait for client to receive new client device settings and configuration baseline to create wmi instance followed by client inventory . Any way that can push the clients report to SCCM in faster way. Click Ok ,next next to see the summary page. Hi Chad, Hi, SQL and Configuration Manager (SCCM) tips, tricks, and ramblings. hi eswar, I, need SCCM 1902, SQL Views for Local Group Members & SQL Query also. Attribute Class: System Resource . For database reporting, check the client inventory log if the wmi namespace picked up and sent the inventory to site server. Below is an example: Certainly a few more steps than scoping in Group Policy! I'd rather not be running the script unless it needs to be run, and I don't need to run it if the WMI object exists. Name= arrUserBits(1) In Active Directory Users and Computers, create a new security group. Query rule. If the namespace exists in WMI,what does the inventoryagent.log tell you ? I'm able to get members of local administrators group. Hi Eswar ... could you please edit the script to fetch the Accounts State "Disabled". This entry was posted in ConfigMgr, Support and tagged database, duplicated objects, query, sccm on December 11, 2012 by Adrian Kielbowicz. My implementation is a mergeof two ideas, and making it scalable. Click OK. Back to Membership Rules page, click Next. Note: Should i go with configuration item or as package ? ,lgm.domain0 [Domain for Account] This blog post will describe how to do a script to create SCCM Collections based on AD OU. So i started creating configuration items ,configuration baseline and do changes to client agent settings (MOF file) ,generate report . oDataObject.Properties_.add "Account" , wbemCimtypeString ,lgm.account0 as [Account Contained within the Group] I have read that this may be a problem since CB1802. Else You can reply on SQL view that are discovered by AD system/security groups . For compliance baseline ,you can try to trigger baseline on the client manually ,check if it is compliant ,if so ,try to run the inventory action ,monitor the results in inventoryagent.log and then on SCCM database. I've check dataldr.log and no errors. Required fields are marked *. If the default query will not even display the security group I assume my user collection query to display all "Leaderships" members will not work either? Now, Iâm going to explain what this query does and how it works. Query 1: List all clients with members of the local Administrators group: select sys1.netbios_name0 http://eskonr.com/2017/03/sccm-configmgr-report-for-local-admins-and-local-group-members/ you can use this to customize your requirements. where lgm.name0='Administrators' oDataObject.Put_, Dim objGroup, strComputer ,strUserPath ,arrUserBits ,wshNetwork ,Domain,Name , Type1 Manythanks to the internet for providing the solution. Great blog post! If you search online with subject line ,you will mostly hit TechNet forum/blogs that refer to the following links. This query simple checks to see if the Client Activity Status is equal to zero. Please ask IT administration questions in the forums. wbemCimtypeString = 8 SCCM is a beast. Is there a way to expand the groups? I have updated the MOF file . Any advice on this would be helpful. I am on SCCM 1902. Linking an AD security group to a SCCM collection, "What is the name of the Application group? This script is designed to be run from the Configuration Manager Server. Set oLocation = CreateObject("WbemScripting.SWbemLocator"), Set oServices = oLocation.ConnectServer(,"root\cimv2") For standardization, name your new collection the same as your security group. Everything I found was related to option 2) Get members of all groups, Could you please have a look and re-add the scripts/files which are needed for option 1 ? Thanks! click next (leave default OS settings) ,next, on settings page ,add new with following information. It is a software deploying, application packing, OS installing, and cappuccino making machine (currently in testing, expected in System Center 2015). Is it possible that 2 users group with the exact same name, within 2 different ADs, members of the same local group, only 1 will be inventory? But all SQL queries are returning local groups and their members for only 1 server. Also for international Windows users: if you want to make a proper select with the WHERE clause you should add N before the international name of your Administrators group, in my case it is Seems to be the case here. 4/10/2020 11:59:09 AM - Found 21 Local Groups In the Configuration Manager console, select Monitoring. I run my query and it's empty. We can now specify the security group that will define our query. where lgm.name0='Administrators' -- and sys1.name0=@pc You can select these changes on custom client agent settings to deploy to collection . Query for Users within a Security Group Using a Variable. 5/13/2018 6:20:00 PM - Cleaned cm_localgroupmembers, if it existed. Eswar - Ok will use the new MOF file (SCCMLocalGroupMembers.MOF) into ciient settings and see, if sql script will work. Hi, select SMS_R_SYSTEM.ResourceID, SMS_R_SYSTEM.ResourceType, SMS_R_SYSTEM.Name, SMS_R_SYSTEM.SMSUniqueIdentifier, SMS_R_SYSTEM.ResourceDomainORWorkgroup, SMS_R_SYSTEM.Client from SMS_R_System where SMS_R_System.SecurityGroupName = "Contoso\\Test_Security_Group" This menu can be found in the top left of the console. For value, specify your group name as: DOMAIN\GROUP Name. Step 1: Copy the MOF file from download section to your SCCM server,import the MOF file into default client agent settingsâ>Hardware Inventory in your SCCM server (CAS if you have else primary site ) ,de-select the settings in default client agent settings for localgroupmembers . 5/13/2018 6:20:00 PM - Completed populating cm_localgroupmembers On client machine after the policy ,assigned configuration baseline is compliant. Find your collection ID in the SCCM console and add it on the $CollectionMembers line. oNewObject.Delete_, ' Create data class structure oNewObject.Name = Name Be sure that Active Directory Group Discovery and Active Directory System Discovery are enabled. I looked at the table dependencies and there at no dependent views for the localgroupMembers table. This can be confirmed by running the wmi query through powershell. Import the MOF file into default client agent settings but do not select the changes in default client agent settings. Deploying a preexisting application to our AD linked collection. 5/13/2018 6:20:00 PM - Not a Domain Controller, Continuing SCCM ConfigMgr report for local admins and local group members, Hi Rome, What certificates are you referring to? I only glanced at the "all groups" script but it looked written differently enough that it probably doesn't have this same issue. Hi Eswar, I am trying to download the configuration baseline cab from the link you provided here. Hi Eswar! Many thanks Note: This task can be achieved in 2 ways ,either by deploying script as package or deploying the script using baseline method ,but Pre-requisite ,is recurring deployment, or Recurring DCM Baseline/CI. Not sure where to double check this. The Information which is stored SQL views that start with V_GS comes from inventory. thanks for the comment. Providea full step by step guide on how to audit members of the localAdministrators group (or any other local groups at the same time) via ConfigMgr. Hi Jason, If you want only members of local admin group ,select localadmins.vbs, Click ok, click next ,on the compliance rules ,click new with the following information, Selected setting: select the setting that you created above, Setting comply rule: This specified script does not return any values. SCCM Clients Collections Clients not approved select SMS_R_SYSTEM.ResourceID, SMS_R_SYSTEM.ResourceType, SMS_R_SYSTEM.Name, SMS_R_SYSTEM.SMSUniqueIdentifier, SMS_R_SYSTEM.ResourceDomainORWorkgroup, SMS_R_SYSTEM.Client from SMS_R_System ⦠Client must run a Machine Policy Refresh (SCCM's version of a GPUpdate). By linking applications to security groups, you can move software deployment tasks to Active Directory. So a customer of mine wanted a report from configuration manager to list primary devices for their users. I have several Operating system images languages. On the Home tab, in the Create group, select Create Query. The heavy lifting is done with a PowerShell script. Thanks. SCCM ConfigMgr report for local admins and local group members I'm going to use these selecter user to further select those of them who don't have some particular software installed. I am not the only one facing issue while importing the cab file, there are lot more people who posted about it on TechNet for solution. Give a try on different OS and let me know the results. Head back to the Configuration Manager console and navigate to Assets and Compliance/Device Collections. If the device has multiple users in admin group then you get multiple rows for the same computer . Bamrung commented on Error changing time zone in Windows Server 2019: Use the command line or PowerShell instead 28 minutes ago, Panny commented on Strings in PowerShell – Replace, compare, concatenate, split, substring 12 hours ago. Values should be available when you click the value button. Remove Disabled Active Directory Computers From SCCM Powershell. Appreciated and thanks for your feedback. We've been running it in our environment for quite a while now! any suggestion on that? Hey, I've added the .MOF file to default client settings, added the .CAB file. with this change ,there will be a SQL view created and can be used for reporting which is : v_gs_localgroupmembers0. Backing up the data in Office 365 is extremely important. I dont have any powershell script that does the similar function however you can create one from the vb script as sample. How to Find Users and thier AD groups in SQL Server - SQL Server DBA Tutorial This video illustrates Following: 1- How to find members of an Active Directory group using SQL Server Management studio (SSMS) 2- How to find members of an Active directory group using T-SQL Script 3- How to find which Active directory group a particular user belong to using T-SQL. Did you check the logs on the computer ? If you see GUID values ,PC has issues reaching out to domain controller/lost the trust. If the Local Administrators group contains a user with a SID instead of a proper "Domain\Username" it will incorrectly identify the username\domain of that SID user. Did the script ran successfully? A portion of this script relies on the Quest AD cmdlets. Also, this way I get a little reporting back and am able to easily see if the script is working properly or not right from the baseline without having to go look through the logfile that is created. Paolo Maffezzoli posted an update 23 hours, 19 minutes ago, Paolo Maffezzoli posted an update 23 hours, 21 minutes ago. WHERE v_gs_localgroupmembers0.Name0 = N'ÐдминиÑÑÑаÑоÑÑ'. what this baseline does it ,when you run ,it pipe the information into wmi and inventory agent will pick this information and send it to site server. I would strongly suggest you go with configuration item and make it recurring instead of scheduling it for 1 time. Can somebody advice me on WQL query to select all users from specified AD groups? Hi, I've checked your code and haven't seen why this is not working. Do le, Hi Jonathan, Yes, it is typo. Delta discovery will ensure that new/updated resources are updated within SCCM. Full discovery updates them just fine, so I have it set running 4 hours for now. Domain users from AD2, Hi I have added both mof files and tried both baselines. Have attached both scripts in the download section for your reference in case you don't want all groups information. I did however notice that the only custom views that I have also have configuration.mof entries. Its functionality is limited. 4/10/2020 11:59:09 AM - Cleaned cm_localgroupmembers, if it existed. but the database only creates the tables and not the views. Domain users from AD1 1) Get members of local administrators group ONLY (WIN32_localadmins) Create SQL Query in SQL Server Management Studio . I am not new to extending inventory. Solution that was provided by Sherry was to create configuration item/configuration baseline with vbscript ,deploy this to collection ,import mof file into client agent settings to pull custom wmi changes that made by script,run report to get the required information. Error 0x80041002". from v_gs_localgroupmembers0 lgm Edited Jan 10, 2016 at 08:11 ⦠I mean, if i report a list of groups that are members of the local Administrators group, can I report the expanded users list? http://myitforum.com/cs2/blogs/skissinger/archive/2010/04/25/report-on-all-members-of-all-local-groups.aspx, https://mnscug.org/blogs/sherry-kissinger/244-all-members-of-all-local-groups-configmgr-2012, http://mnscug.org/images/Sherry/WMIFrameworkForLocalGroupswithLogging.zip. Thanks for pointing it out. Investigate collections that have not updated their membership for over two weeks and remove them from the incremental evaluation cycle. If you have any questions about using Active Directory with SCCM (or about using this script below), just leave a comment! Hoping this can find it's way to people that are running into troubles with this, or needing help with tweaks. List Collection membership of computers - SCCM Continuing from the previous article - where I wrote about SCCM Resource Explorer and how to handle multiple machines when you want to see the inventoried data about them in SCCM - there's another important parameter of computers in SCCM which can be listed: the SCCM Collections computer(s) are member of.